Menu operations 19, Menu operations, Making menu settings 1 – Sony PCM-R300 User Manual

Page 19: Menu descriptions, Set id6, Rec mute (record muting duration), L-sy th (level-sync threshold), L-sy bk (level-sync blank time), Iec s-id (iec start-id), Iec cd-q (iec cd-q code)

Advertising
background image

Menu Operations

19

EN

Menu Operations

Menu Operations

You can make various settings and examine internal
conditions of the deck through menu operations.
Settings made through menu are memorized even
when the deck is turned off.

Note

You can do menu operations only when the deck is empty,
stopped or paused.

= / + (SELECT)

0 / ) (DATA) ENTER

MENU

MARGIN

OPEN/CLOSE

RESET

RESET

MODE

ENTER

MENU

REW

FF

SELECT

DATA

AMS

INPUT

ID

PHONES

SBM

ID MODE

REC MODE

REC

REC MUTING

PAUSE

PLAY

STOP

PHONE LEVEL

REC LEVEL

RENUMBER

REHEARSAL

AUTO

WRITE

ERASE

g

6

5

4

6

0

3

7

2

8

1

9

10

MAX

MIN

ON

48 kHz

44.1kHz

LONG

START

STOP

END

STANDARD

OFF

ANALOG OPT

POWER

COAXIAL

=

p

P

R

r

+

0

)

CH-1 (L)

CH-2 (R)

Making menu settings
1

Press MENU repeatedly until “--MENU--”
appears in the display.

2

Press

=/+ (SELECT) repeatedly to select the

menu.

3

Press

0/) (DATA) repeatedly to select the

parameter.
The selected parameter flashes.

4

Press ENTER.
The selected setting lights up.

5

Press MENU again.
The deck becomes ready for operation.

Menu descriptions

A brief explanation is given below for each menu,
including their settings or setting range, factory setting,
and reference pages.

SET ID6

Selects the copy information to be written on the tape
when recording the analog signal or the IEC-958 digital
signal for broadcasting studio use input from the
DIGITAL COAXIAL IN jack.

Settings:

00 (copying permitted), 10 (copying
prohibited), 11 (one generation copy
only)

Factory setting:

00

Reference page:

5

REC MUTE (RECord MUTing duration)

Sets the duration of the sound-muted section created
between tracks by the Record Muting function.

Setting range:

0.5 to 9.5 seconds (in units of 0.5
second)

Factory setting:

4 seconds

Reference page:

12

L-SY TH (Level-SYnc THreshold)

Sets the reference input level for automatic writing of
start IDs.

Setting range:

–12 to –60 dB (in units of 1 dB)

Factory setting:

–45 dB

Reference pages:

6, 15, 20

L-SY BK (Level-SYnc BlanK time)

Sets the length of time that the input signal must
remain below the reference level before automatic
writing of start IDs begin.

Setting range:

1 to 10 seconds (in units of 1
second)

Factory setting:

3 seconds

Reference pages:

6, 15, 20

IEC S-ID (IEC Start-ID)

Specifies if start IDs (or skip IDs) are automatically
detected and written on the tape when recording from
a DAT deck connected to the DIGITAL COAXIAL or
OPTICAL IN jack.

Settings:

on (start IDs (or skip IDs) are
automatically detected and written),
-- (writing of the start IDs (or skip IDs) is
determined by the settings of the L-SY
TH and L-SY BK menus)

Factory setting:

on

Reference pages:

6, 15, 20

IEC CD-Q (IEC CD-Q code)

Specifies if start IDs are written automatically
whenever a Q code defined by the user’s bits on the
CD is detected while recording from a CD player
connected to the DIGITAL COAXIAL or OPTICAL IN
jack.

Settings:

on (a Q code is detected and written as a
start ID automatically),
-- (writing of the start IDs is determined
by the settings of the L-SY TH and L-SY
BK menus)

Factory setting:

on

Reference pages:

6, 15, 20

(Continued)

Advertising