e-mail: [email protected]

4.3.4 Assembling of the Power Supply and Data Cable (Single Cable Pipe)

The connection of the cable is also done inside of the SAB Cab. Instead of an 2-wire power

supply cable there is now an 5-wire data cable needed. The diameter of the inner wires must

be big enough to keep the voltage drop in the specified range.

The steps to mount the cable is decried in Chapter 4.3.3.

B

A

D

C

E

green

-

+

L

+U

S

-U

S

U

L

black

shielding

NC

shielding

+9..30V

DC

GND (0V)

TXD

RXD

NC

ARE I2

V+

DC

TxD (reader)

GND

RxD (reader)

V+

DC

B

A

C

D

E

green

-

+

L

+U

S

-U

S

U

L

black

NC

shielding

+9..30V

DC

GND (0V)

TXD

RXD

NC

ARE I2

Advertising