6 ec- echo, 7 bd- baudrate – AEG COMPACT READER ARE I2 User Manual

Page 19

Advertising
background image

Manual
Page 19 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

AEG
Identifikationssysteme GmbH

Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: [email protected]

6.6 EC- Echo

The command EC changes of the echo function setting.

Input format:

EC <SP> parameter <CR>

Parameter:

v

Function

0

echo on

1

echo off

Output (example):

0 <CR>

Note:

The default value of the parameter EC depends on the particular
reader.

6.7 BD- Baudrate

The command BD enables the change of the baud rate. The settings are effective after a warm

start using the RST command.

Input format:

BD <SP> parameter <CR>

Parameter:

Parame-
ter

Function

0

4800 baud

1

9600 baud

2

19200 baud

Output (example):

2 <CR>