3start-up procedure – AEG COMPACT READER ARE I2 User Manual

Page 6

Advertising
background image

Manual
Page 6 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

AEG
Identifikationssysteme GmbH

Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: [email protected]

The connection of the cables (power supply and data transfer) is done inside of the connection

cab (SAB Cab). Together with an sealing element a protection classification of IP 65 is guar-

anteed.

By means of the integrated antenna the reader generates an alternating magnetic field, which

powers the transponder. Coded signals sent back from the transponder are received and de-

coded by the reader

The reader is fully controlled by an Master with RS 232 data port, while using the integrated

serial RS 232 Interface of the reader.

The side of the housing showing the antenna symbol must not be brought next to a metal sur-

face. This could lead to a significant change of the properties of the antenna circuit, which in

turn reduces the reading range considerably.

Environmental electromagnetic noise may also reduce the specified reading performance.

Special hints to overcome these problems are documented in Chapter 8.

3

Start-up Procedure

The start-up procedure of the reader system is split up to following steps:

• mounting of the reader and pin connection (cabling), see Chapter 4
• operational instructions, see Chapter 7

To get a feeling how the IdentSystem will work, first start the reader controlled by the se-

rial interface (RS 232) of an isolated PC.

The next step is to integrate the reader to the operating network.