4.3.5 Final Assembly of the Cable Pipe

• Pull by and by all the cable back, until the isolation of the cables are near to beginning of

the cable pipes.

• Fasten nuts (5) of the cable pipes with the right tool (17mm).

• Do this carefully, to ensure the tightness of the protection class of IP 65..

• Plug the finished assembled MINI-COMBICON-Connector to the SAB Cab. Take care of

the correct coding ((7) in Figure 4-2) of the connectors.

4.3.6 Plug in of the SAB Cab

Attention:

Before plugging the SAB Cab to the connectors of the reader, make sure that the

grounding of the device is well done. Otherwise the electronic may be destroyed by elec-

trostatic discharge (ESD).

Figure 4-3: Plug on the SAB Cab

• Put on the sealing 2 to the SAB Cab (A).

• Plug in the SAB Cab to the connector at the bottom of the reader device (B).

• There is only one way to plug in the SAB Cab to the connector rim of the reader.

• Fasten the SAB Cab with the help of the screws.