Input format:

CID <SP> parameter <CR>

Parameter:

Value

Function

0

no filter function , (default value)

1

suppression of repeatedly read IDs

Please note: The CID parameter is only active, if the GT-Command is applied or the reader is

in the Continuos Reading Mode. In the MD 2 anyway a <CR> is sent to the master.

6.4 CN – Suppression of No Reads

Through the setting CN=1 all NoRead results are suppressed on the serial interface..

Input format:

CN <SP> parameter <CR>

Parameter:

Value

Function

0

issue NoReads on serial interface; (default value)

1

suppress NoReads on interface

Output (example): 0 <CR>

Please note: The CN parameter is only active, if the GT-Command is applied or the reader is in

the Continuos Reading Mode. In the MD 2 any way a <CR> is sent to the master.

6.5 NID- Failure Protection

NID specifies the number of identical transponder numbers, which have to appear for the

result “successful reading“ within a reading cycle. In the setting NID = 1, two successive

readings have to show the same transponder number.

Input format:

NID <SP> parameter <CR>

Parameter:

Value

Function