Figure 7.1.2 : Software triggered reading operation with TOR>0

Please note: The TOR parameter is only active, if the GT-Command is applied. Within the

time span defined by the value of TOR no NoRead will be output on the interface!

7.1.1 Settings of the Reader / Most Used Parameters

The default operation mode is changed by sending a software command to the reader.

In combination with an R / W transponder, the serial number of the transponder device is read

out only.

MD 2 -

triggerd by an software command

most used parameters.

CID 0 -

no suppression of repeatedly read Ids

CN 0 -

no suppression of NoReads

NID 1

failure protection.; selection guide 2 out 2 transponder codes

TOR XYZ

maximum reading time after the standard read command

is applied to the reader. The chosen value must match the

timing demands of the production process.

TOR 5

Default value

exciter

processor

interface

TOR

GT

reading process

NoRead

reading cycle reading cycle reading cycle