1 allowed diameter of the used cables, 2 assembling of the cable pipe – AEG COMPACT READER ARE I2 User Manual

Page 8

Advertising
background image

Manual
Page 8 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

AEG
Identifikationssysteme GmbH

Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: [email protected]

Inside of the SAB Cap there are the pins of following connections:

• power supply

• data link to the serial interface RS232

The codes to order the SAB Cabs and preassembled cables are listed below:

ID 70212

SAB-Cab incl. one PG9 cable pipe and 5 wire cable (standard cable)

ID 70213

SAB-Cab incl. one PG9 cable pipe and 5 wire cable / Sub D 9 Connector

(Service Cable)

ID 70221

SAB-Cab incl. one PG9 cable pipe

ID 70215

SAB-Cab incl. two PG9 cable pipes

ID 70219

SAB Cab without any cable pipe. The cabling is done by the customer himself.

4.3.1 Allowed Diameter of the Used Cables

The allowed diameters of the cables used for data link and power supply must be in the range

from

∅3,5 to ∅8mm. For this case, IP 65 is reached.

4.3.2 Assembling of the Cable Pipe

If no preassembled SAB Cab are used (Best-Nr. ID 70214), the assembling must be done in

following way:

• Breakthrough the prepared areas at the surface of the SAB Cabs. There are two prepared

areas seen at the SAB Cab: central and at one side of the cab.

• The sealing must be done in the correct way O-Ring (3) at the cable pipe (4) (see also

Figure 4-1.

1

2

3

4

Figure 4-1:Assembling oft the Cable Pipe

• Bring the nut (2) of the cable pipe inside of the SAB Cab (1).

• To fasten the nut please use the right tool (17mm)..

Advertising