AEG COMPACT READER ARE I2 User Manual

Page 25

Advertising
background image

Manual
Page 25 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

AEG
Identifikationssysteme GmbH

Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: [email protected]

• Wait for the answer

• Analyse the received answer: 3 characters plus <CR>.

<ACK> <CR>

Writing process was successful

<NAK> <CR>

Writing process was not successful.

<NOT> <CR>

The response of the transponder was not readable.

The result of the writing process may also seen at the LED’s.

• LED L2 lit, if there was a successful write

• LED L3 lit, if there was no successful write.

Example

WD <SP> 20 <SP> < 0 1 2 7 A C D F > <CR>

Write to block 20

Allowed Values (block numbers of the transponder IC):

ALGO 9 (1kBit Memory)

3 .... 31

ALGO 6 (2kBit Memory)

16 ... 63