Exhibit 3.2.1-1 fibre channel cable options, Autoconfiguration, Manual configuration – ATTO Technology Diamond Storage Array VT-Class User Manual

Page 22: 1 connecting a fibre channel array, Autoconfiguration manual configuration

Advertising
background image

11

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

3.2.1 Connecting a Fibre Channel Array

The Diamond-VT supports up to two Fibre Channel Host Interface Cards (HIC). Physical connections
and CLI commands contribute to the Fibre Channel topology.

The Diamond-VT may have
two Fibre Channel Host
Interface Cards (HIC). Each
HIC is connected by a Fibre
Channel cable via an SFP
(small form factor
pluggable) module into a

point-to-point or loop Fibre Channel topology.

1

Install the SFP according to the manufacturer’s
instructions.

2

Insert the SFP into the Fibre Channel Host
Interface Card in the back of the Diamond-VT.

3

Insert the correct cable.

The cable you use depends upon your application,
the environment and the distance required for
your storage area network.

To comply with FCC and CE EMI for the 2-
gigabit Host Interface Card, use fiber optic cables.

Exhibit 3.2.1-1 Fibre Channel cable options

Each HIC has two ports and an on-board hub.
Each port has an SFP module to connect to Fibre
Channel. Each HIC is independent of the other, so
that one may be connected into a point-to-point
topology and the other into a loop. However, if

one port in a HIC is connected into a point-to-
point topology, the other port cannot be used.

One of the advantages of using loop topology for
Fibre Channel connections is that it allows
Diamond-VT units to be daisy-chained together.
See Exhibit 3.2.1-2.

Autoconfiguration

The Diamond-VT automatically determines if the
Array HICs are in loop or point-to-point
topologies.

If you wish to see how the unit has been set up, go
to the CLI commands and type

Info

or go to the

Status

page of the ExpressNAV interface. The

return displays the data rate and connection mode
for each HIC (FC 0 and FC 1).

Manual configuration

You may manually configure the Diamond-VT
using CLI commands (see

CLI: Interface via ASCII-

based Commands

on page 27.) or access the Fibre

Channel

page of the ExpressNAV interface.

The

FCConnMode

CLI command specifies the

Fibre Channel topology for both HICs on a
Diamond-VT. Options are loop only (loop), point-
to-point only (ptp), loop preferred (loop-ptp) or
point-to-point preferred (ptp-loop).

Loop connects to either an FC-AL arbitrated loop or
a fabric loop port (FL_Port) on a switch.

Point-to-point (ptp) connects to a direct fabric
connection, such as an F port on a switch.

Loop-ptp allows the Diamond-VT to determine
what kind of connection to use, but tries to connect
in loop mode first, then point-to-point mode.

Ptp-loop allows the card to determine what kind of
connection to use, but tries to connect in point-to-
point mode first, then loop mode.

Cable length

Cable type

Cable
size

<10 meters

Unequalized

copper

>10 <30 meters

Equalized copper

Up to 175

meters

multi mode fiber

optic

62.5

micron

Up to 500

meters

multi mode fiber

optic

50 micron

Up to 10

kilometers

single mode fiber

optic

9 micron

2 Gb HIC uses

2 SFPs to connect up

to 2 FC cables

Advertising