Monitoring, reporting

temperature warning alarm will report OK during
normal operating conditions.

In an abnormal operating condition, such as
blower failure, under high ambient temperatures
when the Diamond internal midplane temperature
reaches a critical point, the temperature alarm will
report

Warning

and activate the audible alarm and

fault LED on the front of the unit. If the internal

midplane temperature were to reach a higher
point, the temperature warming alarm will report

Critical

, the Array will be taken off line, and all

disk drive activity will be disabled. When the
ambient temperature decreases to within standard
operating range, the drives will be powered back
on and the host will be allowed to access the data.

Power Supply Monitoring

The Diamond-VT

monitors the operation of its power supplies and
blower assemblies every 30 seconds. If the status
changes, the system reports it visually with an
LED and a message in the CLI.

If a power supply or blower fails, the management
system sends a CLI message and turns off the
corresponding power supply LED.

The blower assembly directly adjacent a power
supply must be functioning properly for the power
supply to work properly. If a blower assembly
fails, the power supply will shut down and the
management system will send a CLI message.
The corresponding power supply LED on the
system management card will also turn off.

If a good replacement power supply or blower
assembly is inserted into the array, the
management system will send a CLI message and
the corresponding system management card LED
will go on. It may take up to 30 seconds for the
system to note these changes.

System Fault LED and Error Codes

If a serious

hardware or software error occurs in the
Diamond-VT, the System Fault LED will display
a series of flashes or blink codes. Error
information will be reported via the Command
Line Interface if it is operational.

At power up, the green Diamond Array Ready
(RDY) LED turns on after successful completion
of the POST (Power On Self Test) indicating the
array is ready for normal operation.

During operation, the Ready LED will stay lit
even if the amber Fault (FLT) LED lights.

If a serious error occurs in the array, the amber
Fault LED will flash repeatedly in a blink code
pattern:

• an initial series of blinks indicating the system

problem

• a two second pause

• another series of blinks providing more detailed

information for technical personnel.

• a four-second pause

• the blink code sequence will repeat from step 1

until the error is cleared.

In general, any fault will require notification of
Diamond Array technical personnel for resolution
or for further debug instructions. When you report

Exhibit 9.0-1 Typical Diamond-VT operation over a range of external ambient temperatures. Alarms will be
audible, visual, CLI and SES cues as described above.

Temperat

ure

Condition

25°C

blowers OK

25°C

1 blower

fails

32°C

blowers

OK

32°C

1 blower

fails

35°C

blowers

OK

35°C

1 blower

fails

40°C

blowers

OK

40°C

1 blower

fails

Read/Writes

normal

normal

normal

normal

normal

normal

normal

Array offline

Alarms

OK

OK

OK

OK

OK

WARNING

OK

CRITICAL

Number of blinks

Problem area

1, 2 or 3

processor or memory

4

Fibre Channel interface

5

SCSI interface

7

Fibre Channel connection

8

general internal processing

9

SCSI Enclosure Services