Poweraudiblealarm, Raid5cleardatastatus, Raidrebuildstatus – ATTO Technology Diamond Storage Array VT-Class User Manual

Page 51: Serialnumber, Sledfaultled, Smartdata, Tapedriveinfo, Tapevolumeinfo, Temperature, Virtualdriveinfo

Advertising
background image

40

CLI: diagnostics

PowerAudibleAlarm
Silences the audible alarm for a current power supply
failure. The alarm will be activated on the next power
failure.

Immediate command: PowerAudibleAlarm disabled

RAID5ClearDataStatus
Displays the status of RAID5 Clear Data processing. S
represents the sled number, D represents the drive
number. Applies to RAID5 only

Set syntax: RAID5ClearDataStatus

RAIDRebuildStatus
Displays the RAID1, RAID 5 or RAID 10 Rebuild Status
Summary. If no RAID groups are defined, the header
information is displayed with no data. The status
summary contains the RAID1, RAID 5 or RAID 10.The
RAIDRebuildStatus command has no effect on the state
of any rebuild in progress.

Member index and the following fields in tabular form:

S t a t u s

: OK, DEGRADED, IN PROGRESS, or

FAULTED

S l e d N u mb e r

: Location of the sled

C u r r e n t L B A

: Logical block currently being

rebuilt

M a x i m u m L B A :

Last logical block to be

rebuilt

S t a t u s O K

: the RAID1 Mirror is in sync and no

rebuild activity is occurring. The Current LBA,
Maximum LBA and percentage complete values
are not displayed.

S t a t u s D e g r a d e d

: the RAID1 Mirror is out of

sync and is waiting to be rebuilt.

S t a t u s I n P r o g r e s s

: the RAID1 Mirror is out of

sync and a rebuild is occurring on the respective
drive.

S t a t u s F a u l t ed

: the RAID1 Mirror is out of sync

and an error occurred in an attempt to
synchronize the drives in the RAID 1 group.

SerialNumber
View the board serial number, a 10-character field. The
first four alphanumeric characters are an abbreviation
representing the product name. The remaining six digits
are the individual unit’s number.

Get syntax: get SerialNumber

SledFaultLED
Changes the state of the selected sled LED to the
indicated state. Choose the sled number,

1-12,

or

all

, turn

on

or

off

Default: off

Set syntax: set SledFaultLED [ all | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
8 | 9 |10 |11| 12] [ on | off]

SMARTData
Displays the current SMART (Self-Monitoring Analysis
and Reporting Technology) data for the specified drive.

Immediate command: SMARTData [sled#] [drive #]

TapeDriveInfo
Displays information about the named Tape Drive
including LUN, Tape Volume ID and state of the tape
drive.

Get syntax: TapeDriveInfo [tape drive #]

TapeVolumeInfo
Displays information about the named Tape Volume
including Volume ID, LUN, Virtual Disk ID, Partition ID,
Total capacity and percentage of capacity used.

Get syntax: TapeVolumeInfo [tape volume #]

Temperature
Returns the current internal temperature of this Diamond
Storage Array in degrees Celsius. The value is read only.

Get syntax: get Temperature

VirtualDriveInfo
Displays the named Virtual Drive definitions.

Get syntax: VirtualDriveInfo [active|planned] [Virtual
Drive ID]

ZoneInfo
Displays the named zones’ definitions. Information about
the Active Zone Configuration is the default; if you want
information about the Planned Zone Configuration, type
ZoneInfo Planned zone_name.

Zone syntax: ZoneInfo [Planned] [zone_name] [all]

ZoneState
Changes the specific state of a zone. The ZoneState
command must be entered as enabled to activate the zone
before using the ZoneCommit command (which makes
the Planned Zone Configuration the Active
configuration).

Default: disabled
Set syntax: ZoneState zone_name [enabled|disabled]
Get syntax: ZoneInfo

Advertising