2 resetting defaults, Default, Return to default settings – ATTO Technology Diamond Storage Array VT-Class User Manual

Page 74: Factory default, Default return to default settings factory default, Resetting defaults

Advertising
background image

63

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

9.2 Resetting Defaults

Resetting the Diamond-VT to defaults will not alter the RAID configuration, zoning configuration, IP
configuration or Telnet information. However, resetting the Diamond-VT to factory defaults is a last-ditch effort
to recover from corrupt configurations or complete failure. All data will be lost, but the zoning configuration will
remain.

CAUTION

CAUTION

Data will be lost if you follow these
procedures. Make sure you have no other
choice before resetting the Diamond-VT to
factory defaults.

Default

If you need to return to the default settings of the
Diamond-VT but do not want to lose data or Ethernet
settings, use the CLI command

RestoreConfiguration

default

in CLI mode or in the Advanced CLI

configuration page of the ExpressNAV interface.

Note

Using

RestoreConfiguration default

or

RestoreConfiguration factory default

will not

affect the zoning configuration. To restore the
Diamond-VT to factory default, type

ZoneClearAll
ZoneCommit

Return to Default settings

1

Connect to Diamond-VT services via the RS-232
port or the optional Ethernet management
services card (see

Accessing the Diamond-VT

on

page 15). You should now be in Command Line
Interface. Continue with the CLI or access the
ExpressNAV interface (see

ATTO ExpressNAV:

Browser-based Interface

on page 23).

Note

Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in ExpressNAV.

2

Type

RestoreConfiguration default

to reset the

system configuration (See Exhibit 9.2-2 for a list of
configurations which will be changed).

3

Type

FirmwareRestart

or cycle power of the

Diamond-VT.

4

Reboot the host PC after the Diamond-VT
completes its power on cycle.

Factory Default

Resetting the Diamond-VT to factory defaults is a last-
ditch effort to recover from corrupt configurations or
complete failure. All data will be lost.

Note

Using

RestoreConfiguration default

or

RestoreConfiguration factory default

will not

affect the zoning configuration. To restore the
Diamond-VT to factory default, type

ZoneClearAll
ZoneCommit

To reset to Factory Defaults, firmware version
2.5.3 or higher

1

Connect to Diamond-VT services via the RS-232
port or the optional Ethernet management
services card (see

Accessing the Diamond-VT

on

page 15). You should now be in Command Line
Interface.

2

Continue with the CLI or access the ExpressNAV
interface (see

ATTO ExpressNAV: Browser-based

Interface

on page 23).

Note

Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in ExpressNAV.

3

Type

RestoreConfiguration factorydefault

to reset

the system configuration. (See Exhibit 9.2-2 for a
list of configurations which will be changed).

4

Type

FirmwareRestart

or cycle the Diamond-VT

power.

5

Reboot the host PC after the Diamond-VT
completes its power on cycle.

Advertising