Factors to consider, Status and sense data, Factors to consider status and sense data – ATTO Technology Diamond Storage Array VT-Class User Manual

Page 63

Advertising
background image

52

Zones

the Active configuration will be copied into the
Planned configuration.

To determine what is in the Planned
configuration, type

ZoneInfo Planned

.

Active configuration

is persistent and establishes

the Diamond zoning configuration after power-
up.

The Planned configuration becomes the Active
configuration after successful execution of the

ZoneCommit

command. The Active

configuration is replicated as the Planned
configuration after the successful

ZoneCommit

,

after power-up and after

ZoneRetrieve

. This

replication eases incremental modifications to the
current zone configuration: you only need to enter
changes. Modifications to the Planned
Configuration made before

ZoneCommit

are not

persistent and are lost in the case of power-up.

To determine what is in the Active Configuration,
type

ZoneInfo.

Factors to consider

Several factors must be considered when
configuring a Diamond-VT with zones:

• Be careful when changing Diamond-VT zoning

configurations. Internal validation logic cannot
detect misconfigurations.

• The Diamond-VT zoning may be driven by

external applications which handle
considerations such as aliasing of parameters.

• Stopping or pausing I/O operations during

zoning changes is the responsibility of the host
computer, external to the Diamond-VT.

• You must refer to a device by a consistent LUN

across zones in accordance with Fibre Channel
specifications.

• RAID configuration changes require planning

and preparation independent of whether any
zones are enabled. Such changes affect data
integrity, and any write to an incorrect LUN may
result in data corruption.

• Degraded operation and RAID rebuilding occur

at a lower level than the Zoning features. SCSI
command operation continues to operate, and
you can modify the Zoning configuration via the
ZoneCommit command at any time.

• Zone validation of switch/fabric routing is not

supported. The Diamond-VT operates within a
SAN environment including host systems, host
bus adapters, switches and other devices. The
Operating System you use may limit zoning
flexibility in your SAN.

• You may create up to 32 zones. Each zone may

have up to two ports, up to 24 devices and up to
32 hosts.

Status and Sense Data

Commands sent to a device may be rejected with sense key, code, qualifier as follows:

LOGICAL UNIT NOT CONFIGURED: 68 00 00

No such LUN exists; the initiator does not have access
to this LUN

LOGICAL UNIT NOT SUPPORTED: 25 00 00

The Logical unit is not in an accessible zone

LOGICAL UNIT NOT READY: 04 03 00

The Logical unit is in an accessible zone, but is not
ready; it may be offline or busy

If the logical unit inventory changes for any reason, including completion of initialization,
removal of a logical unit, or creation of a logical unit, the device server generates a Unit Attention
command for all initiators, telling them a

ZoneCommit

procedure has been successful. The device

server sets the additional sense code to

REPORTED LUNS DATA HAS CHANGED: 3F 0E 00 (LUN has been added to or removed from the zone)

Advertising