ATTO Technology Diamond Storage Array VT-Class User Manual

Page 67

Advertising
background image

56

Update firmware

3

Copy the latest Diamond-VT image file
(“...”.ima) onto the host computer and note its
directory

c:\diamond\flash\“...”.ima

4

Change directories to the place where you
copied the “...”.ima file

cd c:\diamond\flash

5

Open an FTP session using a user-defined IP
address or the default (10.0.0.1) if it has not
changed. The IP address must be a valid
address for your network.

6

At the FTP login prompt, type sysadmin as the
userID.

7

Press Enter at the password prompt.

8

Type put “...”.ima.

The Diamond should acknowledge receiving
the file and display a message not to interrupt
power for 90 seconds.

9

If upgrading the firmware from versions older
than 2.5.3, follow the procedures outlined in

Resetting Defaults

on page 63.

10 When the flash procedure is complete, cycle

power on the Diamond-VT.

CAUTION

CAUTION

Do not interrupt the flash process. If the
process is interrupted, the Diamond-VT
will become inoperable and will have to
be returned to the factory for repair.

Do not turn off the Diamond-VT until the
display returns the Ready prompt.