SER

VICING

1

2

3

4

Servicing Procedure:

12.1

Disconnect/isolate the oven from the power

12.1.1

supply.

Check the oven is correctly installed as

12.1.2

described in the Installation Instructions (Product

Details section).

Visually check the cleanliness/condition of the

12.1.3

power supply/cable/gland, oven casing, cavity and

door for signs of wear, damage, distortion etc., if

required, refer to the ‘Spares & Replacement’ section.

Complete an ‘Earth/Insulation test’ (Testing

12.1.4

Components section) on the oven before switching

on.

Check the display for Error messages, if

12.1.5

an Error is shown, refer to ‘Errors & Diagnostics’

(Servicing section).

Note; If a Firmware update is required, follow

12.1.6

the instructions under ‘Firmware Updates’ (Servicing

section) before continuing with the service

procedure.

Enter Service mode:

12.2

On start up, tap the top right of the main menu

1

screen to bypass oven preheat.
Enter the authorised user password, for

2

example, MANAGER and select OK to display the

Settings menu.
Select the spanner symbol.

3

Enter the service password, for example SERVICE

4

on the keyboard and select OK to display the

error log, service information and test options.

Check the Error Log for details of any logged

12.2.1

oven errors. See ‘Errors & Diagnostics’ (Servicing

section) for more details.

Check the ‘Oven Counters’ to find the usage

12.2.2

of components and the Controls area temperature

within the cabinet. (‘Errors & Diagnostics’, Servicing

section).

Check the operational performance of the

12.2.3

main components using the Visual or Data View

(‘Errors & Diagnostics’, Servicing section).

Perform the Oven tests, (Testing Components

12.2.4

section). If required refer to the ‘Spares and

Replacement’ section for any repairs needed before

continuing with the Oven Tests.

Follow the procedures under the

12.2.5

‘Commissioning’ section before commissioning the

oven for use.

SERVICING THE OVEN

12

DANGER:

BEFORE REMOVING THE OVEN CASING, ISOLATE THE

OVEN FROM THE MAINS ELECTRICITY POWER SUPPLY;

SWITCH OFF, DISCONNECT OVEN PLUG FROM WALL

SOCkET, TURN OFF ISOLATOR SWITCH TO DISCONNECT

FIXED WIRED OVENS AND LOCk-OFF.

WARNING:

ALLOW OVEN TO COOL AND OBSERVE AND FOLLOW ALL

SAFETY PRECAUTIONS INCLUDING THOSE DESCRIBED

UNDER THE SAFETY REGULATIONS SECTION OF THIS

MANUAL BEFORE ATTEMPTING A SERVICE OR REPAIR.

CAUTION MICROWAVE EMISSIONS:

DO NOT BECOME EXPOSED TO EMISSIONS FROM THE

MICROWAVE GENERATOR OR PARTS CONDUCTING

MICROWAVE ENERGY.

Advertising