TESTING

COMPONENT

S

A

C

B

OVEN TESTS

15.4

Enter Service mode (Servicing section).

15.4.1

Select the down arrow to display the

15.4.2

individual Oven tests (A) for the oven to perform.

Microwave Power Test

15.5

Measuring the power output.
Note: The power output is established under IEC

705 standard method which is only workable in

Laboratory controlled conditions. Power output is also

affected by line voltage under load, so this test is an

approximation only.

Ensure the oven is cold, then enter Service

15.5.1

mode to bypass oven preheating.

Select Visual View (B) to check the oven cavity

15.5.2

temperature reading is as close to 0°C as possible.

Fill a microwave safe container (glass or plastic)

1

with one litre (1.78 pints) of tap water at about

20°C (68°F).
Measure and record the water temperature in

2

the container using a thermometer capable of

reading ±0.1 degree increments.
Place the container centrally inside the oven.

3

Select ‘Microwave Power Test’ (C) from the

4

service mode tests. (Microwave power 100% for

63 seconds, fan minimum).
When the countdown has finished, remove the

5

container from the oven, immediately stir with

a plastic implement and measure the water

temperature.
Calculate the temperature rise of the water (end

6

temperature minus the start temperature).

If the temperature rise is outside these limits:

Check the microwave circuit and components,

(Testing Components section).

The Temperature Rise should be:
e3EE & e3XE 10°C (50°F) ±5%
e3XX 14.3°C (58°F) ±5%