Merrychef eikon e3 User Manual

Page 32

Advertising
background image

32

Service & Parts Manual original Instructions
Part Number 32Z3812 US
Issue 1

TESTING

COMPONENT

S

A

A

Soak Test

15.8

Checking the oven cavity integrity.
Procedure:

Place an oven/microwave safe container with

15.8.1

approx. 2 litres of water into the oven.

Close the oven door and select ‘Soak Test’ (A)

15.8.2

from the Service mode oven tests (maximum oven

temperature, 50% microwave power, maximum fan

speed).

Run the test (30 minutes), carefully checking

15.8.3

the oven casing, joints and door seal for signs of

steam or water escaping from the oven cavity.

If necessary, rectify any leaks and repeat the

15.8.4

test.

Safely remove the container from the oven.

15.8.5

Recommission Test

15.9

The Recommission tests are performed following

the completion of a service or repair to ensure

the oven is operational before handing back to

the customer.
Some of the tests have a countdown timer where

failing to carry out a test within the time limit will

cause a test failure and the Recommission test will

have to be restarted.
Procedure:

Select ‘Recommission Test’ (A) from the

15.9.1

service mode oven tests and follow the on screen

instructions to perform the tests. Do not select the

red ‘X’unless you want to stop the test.

After a test has successfully passed, select OK

15.9.2

to continue.

When all the tests have been successfully

15.9.3

performed the display shows the Recommission test

has passed, select OK to confirm.

In the event of a Recommission test failure,

15.9.4

the detail will be recorded in the Error log. Any error

should be rectified and the Recommission test run

again.