COMMISSIONING

Commissioning the oven

25

Initial installation

25.1

Unpack the Oven and check for damage.

1

Check Oven Accessories.

2

Check location will provide adequate Ventilation.

3

Locate Oven onto a strong, level, non-flammable

4

Surface.
Remove panels & check all wiring and components for

5

security.
Refit panels.

6

Position the Oven with a minimum air gap of 50mm,

7

sides & rear.
Check Electrical supply and connect.

8

Place a container of water within the oven and switch

9

it on.

Record Model version & check against serial plate.

10

Record BTS (UI) version.

11

Record SRB version.

12

Record Serial Number & check against serial plate.

13

Enter Service Mode.

14

Record Voltage & Frequency.

15

Record Magnetron Current Draw.

16

Check for Microwave leakage.

17

Record Heater current.

18

Check door opening on display.

19

Check filter removal on display.

20

Check fan speed.

21

Turn off the oven and remove the water.

22

Switch on oven and run up to temperature.

23

Operate Oven, Cooking a Standard Batch.

24

Supply User information & contact details to Customer.

25

Instruct Users with an Overview of the equipment,

26

Operation & Safety (Hazards).

Complete Service Report.

27

After Service

25.2

Complete the following checks after the Oven has been

Serviced/Repaired/Tested before connecting to the

mains electricity power supply:

All internal electrical connections are correct (see

25.2.1

wiring diagrams).

All wiring insulation is correct and is not touching

25.2.2

any sharp edges.

All grounding connections are electrically and

25.2.3

mechanically secure.

All door safety interlocks are secure and

25.2.4

mechanically sound.

The door activates all of the door interlock switches

25.2.5

and in the correct order.

The door operation is smooth, and the arms run

25.2.6

freely in the slots.

The temperature sensor is correctly connected to

25.2.7

the SRB.

The casing is securely refitted with no trapped wires.

25.2.8
Before finishing a service call, recheck the following

points:

Run the Recommission tests to ensure the oven is

25.2.9

functioning correctly and the touch screen is working.

Microwave emissions are below permissible limit of

25.2.10

5mW/cm².

The power output of the oven is checked in

25.2.11

accordance with the procedure.

The oven has correct 50mm (2 inches) air gap all

25.2.12

round and 50mm (2 inches) above. Air flow should not be

restricted.

Complete the Service Report.

25.2.13

Advertising