Service & Parts Manual original Instructions

Part Number 32Z3812 US

Issue 1

31

TESTING

COMPONENT

S

A

B

C

D

E

Temperature Control Test

15.7

Measuring the oven cavity temperature.
(Note; re-calibrating the Thermocouple with the SRB

is normally only required when the Thermocouple has

been replaced or the oven is under or over cooking.)
Procedure:

Place the probe of a temperature reader (A)

15.7.1

onto a heat sink in the centre of the oven cavity and

close the oven door.

Select ‘Temperature Control Test’ (B) from the

15.7.2

service mode tests. The oven heats up and cycles

at the maximum set point temperature over 30

minutes.

Once the oven is up to maximum

15.7.3

temperature check for a stable temperature reading.

Select the red X to finish the test, if necessary.

15.7.4

If the temperature reading is different to the

15.7.5

maximum set point, scroll up (C) to select TEMP.

COMP. (Temperature Compensation) (D) and enter

the password.

Enter the figure from the temperature reader

15.7.6

on the keypad (E) and select OK to calibrate the SRB

to the thermocouple.

Retest to check that the oven cavity

15.7.7

temperature reading is the same as the oven

maximum set point temperature.
If the temperature reading is unstable:

Disconnect and isolate the oven from the

1

electricity supply.
Allow the oven to cool down.

2

Remove the oven casing.

3

Check the cavity temperature sensor wire and

4

connections.
If the wire and connections are ok; replace

5

the cavity temperature sensor (see Spares &

Replacement section).
Replace oven casing, switch ON and retest.

6

If the temperature is still unstable repeat steps 1

7

to 3, replace the SRB (see Spares & Replacement

section), repeat step 6. NOTE: reuse the existing

PM (Personality Module) on the new SRB (enter

Serial No. on reboot).

Repeat the Temperature Control Test

15.7.8

procedure.