2 byosdptzaspectget, 3 byosdptzaspectsave, 90 ptz enabling – Kramer Electronics VP-790 User Manual

Page 100: 1 byosdptzenablesetsave, Ptz enabling

Advertising
background image

96

VP-790 Protocol - API Functions

2.89.2 byOsdPtzAspectGet

API index: 3238
Retrieves the Aspect Lock setting from cache or from the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: On

1: Off

Aspect Lock setting on or off.

2.89.3 byOsdPtzAspectSave

API index: 3239
Saves the Aspect Lock setting from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.90 PTZ Enabling

2.90.1 byOsdPtzEnableSetSave

API index: 3220
Enables PTZ and saves the setting in the SPD immediately.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: Off

1: On

PTZ enabling

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising