VP-790 Protocol - API Functions

2.85 PiP/Multiple Unit Operation Mode

2.85.1 byOsdPIPEBOperationModeSet

API index: 3172
Switches between PiP mode and Multiple Unit Mode. Multiple Unit mode does not

support PiP, whereas PiP mode does not support Edge Blend and PC tool

generated warp maps.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: PiP Mode

1: Multiple Unit Mode

Sets the operation mode.

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.85.2 byOsdPIPEBOperationModeGet

API index: 3173
Retrieves the operation mode.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: Off

1: S-Curve

2: Align Pattern

Retrieves the operation mode set.

2.85.3 byOsdPIPEBOperationModeSave

API index: 3174
Saves the operation mode from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise