Hue 55, Byosdhueset, Byosdhueget – Kramer Electronics VP-790 User Manual

Page 59: Byosdhuesave

Advertising
background image

VP-790 Protocol –

API Functions

55

2.45

53B

Hue

2.45.1

267B

byOsdHueSet

API index: 151
Sets the hue value.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0x00000000: -180°

0x7FFFFFFF: 0°

0xFFFFFFFF: +180°

Hue value

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.45.2

268B

byOsdHueGet

API index: 153
Retrieves the hue value from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0x00000000: -180°

0x7FFFFFFF: 0°

0xFFFFFFFF: +180°

Hue value

2.45.3

269B

byOsdHueSave

API index: 152
Saves the hue value from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise