Netmask, Osd enabling/disabling, Bysetsubnetmask – Kramer Electronics VP-790 User Manual

Page 81: Bygetsubnetmask, Byosdenableset

Advertising
background image

VP-790 Protocol –

API Functions

77

2.69

77B

Netmask

2.69.1

334B

bySetSubnetMask

API index: 113
Sets the netmask and saves the setting in the SPD immediately.

Input Parameters

Name

Type

Range

Description

Value

STRING

nnn.nnn.nnn.nnn

String with 15 ASCII

characters /0 terminated

Netmask

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.69.2

335B

byGetSubnetMask

API index: 114
Retrieves the IP address from the SPD.

Input Parameters

Name

Type

Range

Description

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

STRING

nnn.nnn.nnn.nnn

String with 15 ASCII

characters /0 terminated

Netmask

2.70

78B

OSD Enabling/Disabling

2.70.1

336B

byOsdEnableSet

API index: 3373
Switches off the OSD.
Note; This command only applies to HQView/LEDView with front panel LCD.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: off

1: on

Switches the OSD on/off.

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising