background image

VP-790 Protocol –

API Functions

27

2.17

25B

Black Level Uplift

2.17.1

182B

byOsdEdgeBlendBlackLevelTopl/Top/Topr/Midl/Mid/Midr/Botl/Bot/Bo

trSet

API indices: 3130/3133/3136/3139/3142/3145/3148/3151/3154
The black level is increased for the various blend regions (9 possible regions).

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0 ... 25

Uplift Value

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.17.2

183B

byOsdEdgeBlendBlackLevelTopl/Top/Topr/Midl/Mid/Midr/Botl/Bot/Bo

trGet

API indices: 3131/3134/3137/3140/3143/3146/3149/3152/3155
Retrieves the black level uplift values from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0 ... 25

Uplift Value

2.17.3

184B

byOsdEdgeBlendBlackLevelTopl/Top/Topr/Midl/Mid/Midr/Botl/Bot/Bo

trSave

API indices: 3132/3135/3138/3141/3144/3147/3150/3153/3156
Saves the black level uplift values from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising