3 byosdcolortempsave, 22 component mode, 1 byosdcomponentmodeset – Kramer Electronics VP-790 User Manual

Page 36: 2 byosdcomponentmodeget, 3 byosdcomponentmodesave, Component mode

Advertising
background image

32

VP-790 Protocol - API Functions

2.21.3 byOsdColorTempSave

API index: 350
Saves the color temperature value from the cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.22 Component Mode

2.22.1 byOsdComponentModeSet

API index: 2959
Sets the component input mode.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: 3-wire

1: 4-wire

2: Automatic

Component mode

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code

otherwise

2.22.2 byOsdComponentModeGet

API index: 2960
Retrieves setting for the component mode from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code

otherwise

Value

UWORD32

0: 3-wire

1: 4-wire

2: Automatic

Component mode

2.22.3 byOsdComponentModeSave

API index: 2961
Saves the setting for the component mode from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising