87 pip size, 1 byosdabsolutepipsizesetsave, 2 byosdpipsizeget – Kramer Electronics VP-790 User Manual

Page 98: 88 pip v-pos, 1 byosdpipyset, Pip size, Pip v-pos

Advertising
background image

94

VP-790 Protocol - API Functions

2.87 PIP Size

2.87.1 byOsdAbsolutePipSizeSetSave

API index: 2974
Sets the PiP mode and saves the setting in the SPD immediately.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: Small

1: Medium

2: Large

PIP size

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.87.2 byOsdPipSizeGet

API index: 361
Retrieves the PiP size setting from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: Small

1: Medium

2: Large

PIP size

2.88 PIP V-Pos

2.88.1 byOsdPipYSet

API index: 3214
Sets the PiP Vertical Position.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0 ... 100

PIP Vertical position in % of the main

image, i.e. 0% PiP top edge aligns

with main top edge and 100% PiP

bottom edge aligns with bottom edge.

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising