VP-790 Protocol –

API Functions

95

2.88.2

389B

byOsdPipYGet

API index: 3215
Retrieves the PiP Vertical Position from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0 ... 100

PIP Vertical position in % of the main

image, i.e. 0% PiP top edge aligns

with main top edge and 100% PiP

bottom edge aligns with bottom edge.

2.88.3

390B

byOsdPipYSave

API index: 3216
Saves the PiP Position setting from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.89

97B

PTZ Aspect Ratio Lock

2.89.1

391B

byOsdPtzAspectSet

API index: 3237
Gives access to the vertical zoom slider for asymmetric zoom/shrink when Aspect

Lock is Off.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: On

1: Off

Switch Aspect Lock on or off.

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Advertising