116 vertical position, 1 byosdmainverticalset, 2 byosdmainverticalget – Kramer Electronics VP-790 User Manual

Page 124: 3 byosdmainverticalsave, Vertical position

Advertising
background image

120

VP-790 Protocol - API Functions

2.116 Vertical Position

2.116.1 byOsdMainVerticalSet

API index: 365
Sets the vertical position of the input image.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0 .. Vtotal-VSync-

Vbackporch

Vertical input position

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.116.2 byOsdMainVerticalGet

API index: 367
Retrieves vertical position from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0 .. Vtotal-VSync-

Vbackporch

Vertical input position

2.116.3 byOsdMainVerticalSave

API index: 366
Saves the vertical position from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise