56 lti level, 1 byosdstiltiset, 2 byosdstiltiget – Kramer Electronics VP-790 User Manual

Page 68: 3 byosdstiltisave, Lti level

Advertising
background image

64

VP-790 Protocol - API Functions

2.56 LTI Level

2.56.1 byOsdSTILTISet

API index: 608
Sets the level of the LTI (Luma Transient Improvement) filter.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: Off

1: Low

2: High

LTI value

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.56.2 byOsdSTILTIGet

API index: 610
Retrieves the level of the LTI filter from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: Off

1: Low

2: High

LTI value

2.56.3 byOsdSTILTISave

API index: 609
Saves the level of the LTI filter from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise