Caution:
The inverter(s) used in this example should have the possibility
of declaring at least two rotation speeds depending on the
inputs’ states.

16. After applying the first ingredient software starts dosing the next

ingredient according to the method described above using the
next section (outputs, motor, inverter).

17. The procedure repeats until the last ingredient is applied.

18. The process of dosing can be stopped any time, especially in

emergency situations, by using the EMERGENCY STOP button.

19. After the whole recipe is applied another output (declared in

parameters) is on and chute is performed. It is possible to set
an additional input (see inputs’ declaration parameters) that
will receive the signal of chute permition for the recipe.

20. When the chute process is performed software controls the

mass and if it reaches a value lower than the one set in -LO-
parameter software starts counting down the time declared
in <P7.4.5. CHUTE TIME> before the chute is closed.

21. After the mixture is poured down the program is ready

to start the next dosing process.



32.4. Example of designing non-standard printouts

„RADWAG”

DATE:

TIME:

MASS:

SIGNATURE:.........

After entering the non-standard printouts edition (see ch. 17.5.) we design
the printout:

„ R A D W A G ” \ C \ T D A T E : % 0 0 2 \ C \ T T I M E: % 0 0 3 \ C \ T
M A S S : % 0 0 0 \ C \ C \ T \ T S I G N A T U R E : . . . . . . . . . . \ C \ 0