Clear data, Logical units, Rebuild – ATTO Technology Diamond Storage Array S-Class User Manual

Page 39: Configuration, Advanced, Restart, Help

Advertising
background image

28

ExpressNAV

Refer to

Configuring Drives

on page 49 and

Drive

Configuration Commands

on page 45 for more

information.

Clear Data

Allows you to

• view the status of any Clear Data commands in

progress

• view the rebuild state of each sled
• initialize a RAID Level 5 Clear Data command
• set a rebuild state for each sled
• change the RAID Interleave.parameter
• Enable/disable

AutoRebuild

Refer to

Drive Configuration Commands

on page 45

for more information.

Logical Units

Gives information on the logical units which have
been configured on the array and allows you to
change the status from online or offline or
degraded.

Refer to

Determining Drive and Sled Designations

on

page 15 and

Drive Configuration Commands

on page

45 for more information.

Rebuild

Shows the current status of rebuilds on the array
and allows you to halt, resume or initiate rebuilds.

Refer to

Drive Configuration Commands

on page 45

and

Rebuilding RAID Configurations

on page 65for

more information.

Configuration

Contains the necessary information to manage the
array. Configurable options are

• User

name

• Password (old password, new password,

confirm password)

• Minimum

operating

temperature

• Maximum operating temperature
• Identify

Diamond

• Restore

defaults

Refer to

Maintenance Commands

on page 43 for

details.

Advanced

Allows you to input any CLI command available
through the array.

To use the advanced page CLI commands

1

After the page opens and the Ready prompt
appears, type in the CLI command

2

Click the Submit button: this is equivalent to
typing the CLI command into a telnet or serial
port CLI session.

A text field beneath the box will list the most
recent commands issued to the array through
this page.

3

Type saveconfiguration norestart

4

Click the Submit button. Your changes will be
implemented.

5

To keep the changes through the next power
cycle, type firmwarerestart or go to the
Restart page and click Restart.

Restart

Allows you to implement a firmware restart of the
array. Access is via the Restart link on the left
side of the page.

Note

Restarting the firmware may take a few
minutes.

1

Click the Restart button.

A box displays a message to wait until the
counter gets to 0 and then the browser will
refresh.

2

If the browser does not refresh after the counter
gets to 0, click the link to refresh it manually.

Help

Gives help information about CLI commands and
troubleshooting tips.

Provides links to pages with help text for each
category of options and one link to the
Troubleshooting Tips and FAQs page on the
ATTO website. Contact information for getting in
touch with ATTO technical support is on the right.

When you click a red text box on any page,
ExpressNAV asks for your login information,
then a dialog box opens with help text.

Advertising