Configure drives with CLI commands

DriveWipe
Initializes a drive: wipes it of all data. Drive must be
offline

Set syntax: DriveWipe [Destination Sled] [Dest Drive]
Requires a SaveConfiguration Restart command

IdeTransferRate
Sets the DMA mode transfer rate for all devices.

Choices: 0, 1, 2, 3, 4

Default: 4

Set syntax: set IdeTransferRate [0 | 1 | 2 | 3 | 4]
Requires a SaveConfiguration Restart command
Get syntax: get IdeTransferRate

LUNInfo
Displays information about all LUNs (logical unit
numbers) or detailed information about a specific LUN.
Do not specify a LUN to get information about all LUNs.
Specify a LUN to get detailed information about that
individual LUN. For examples, refer to Information
Commands Results
on page ii
.

...

Get syntax: get LUNInfo [LUN]

LUNState
Sets the LUN to the specified state. May be used to
facilitate removal and insertion of sleds and RAID groups
during power up/power down of sleds.

Default: online
Set syntax: set LUNState [LUN number] [online|offline]
Get syntax: get LUNState [LUN number]

QuickRAID0
Specifies the RAID Level 0 configuration for the system.
The default 0, or no RAID groups, configures the
Diamond Storage Array in a JBOD configuration.
DRIVE indicates drives on one side of the array are
adjacent members of the same stripe group while SLED
indicates the two drives on the same sled are adjacent
members of a stripe group.

Choices: 0, 1, 2, 3, 4, 6,12
Set syntax: set QuickRAID0 [0|1|2|3|4|6|12][drive| sled]
Requires a SaveConfiguration Restart command

QuickRAID1
Specifies the RAID Level 1 configuration for the system.
Sets the system to a mirrored array of spanned drives.
Causes the Configuration Manager to “stamp” the new
configuration onto the drives to take effect at the next
system startup. Setting QuickRAID0 0 removes all RAID
configurations and creates a JBOD.

Set syntax: set QuickRAID1 <Number Hot Spare sleds>
Requires a SaveConfiguration Restart command

QuickRAID5
Specifies the RAID Level 5 configuration for the system.
Sets the system to spanned drives with parity information.
Causes the Configuration Manager to “stamp” the new
configuration onto the drives to take effect at the next
system startup.

Setting QuickRAID5 0 removes all RAID configurations
and creates JBOD.

Setting QuickRAID5 ALL creates one group that
includes all contiguous sleds (minus Hot Spare sleds if
applicable).

To complete RAID Level 5 setup, the RAID5ClearData
command must be issued after the Diamond Storage
Array has been restarted: DO NOT remove power from
the array during this operation.

Choices: 0, 1, 2, 3, 4, all
Set syntax: set QuickRAID5 [1 | 2 | 3 | 4 | all] <Number Hot
Spare sleds>
Requires a SaveConfiguration Restart command
Get syntax: DriveInfo

QuickRAID10
Specifies the RAID Level 10 configuration for the
system; sets the system to a mirrored array of spanned
drives and causes the Configuration Manager to “stamp”
the new configuration onto the drives to take effect at the
next system startup. Setting QuickRAID10 0 removes all
RAID configurations and creates a JBOD.

Choices: 0, 1, 2, 3
Set syntax: set QuickRAID10 [1|2|3] <Number Hot Spare
sleds>
Requires a SaveConfiguration Restart command