ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

7.1 Hot Swap Operating Instructions

To maintain array up time, individual disk drive sled assemblies, power supplies and blower assemblies can be
replaced with the unit fully operational. Special instructions need to be followed to perform these operations.

Disk drives

The following cautions must be observed when hot
swapping disk drives.

• Individual disk drive sled assemblies may be

replaced while the array is operating with no
other intervention only if there is absolutely no
activity
on that drive. Failure to ensure no activity
may destroy any data on that drive and possibly
stop the entire array operation. Follow the
instructions below using CLI commands to
replace drives.

• Removing a drive sled that is part of a RAID

Level 0 group will result in the loss of all data in
the groups associated with that sled. Follow
your backup procedures when removing sleds.

• Do not leave empty openings on the front or rear

of the array under any circumstances. Empty
openings affect airflow and may cause the unit
to overheat and shut down.

• All modular components must be replaced by

qualified personnel only. Components are
electrostatic sensitive. Use a static wriststrap
when handling any of the cards inside the array.
Use proper grounding methods. Always store
spare components in proper ESD containers
when not in use.

Follow your backup procedures before removing a
sled. You may copy drives using the appropriate CLI
commands (Refer to Drive Configuration Commands on
page 45)
.

The following method is the safest way to perform a
hot swap of a drive.

The general approach: identify the disk drive sled to be
replaced, take it offline using the appropriate CLI
commands, turn off its power using CLI commands,
remove and replace with a new disk drive sled, power
up the new sled, and place back on line.

1

Connect to Diamond Storage Array services
(refer to

Accessing the Array

on page 17) and

enter the Command Line Interface mode.

2

The fault LED should be blinking on the disk
drive sled to be replaced. If it is not, type set
SledFaultLED [n] on
. The LED of the drive
you want [n] will light.

3

Determine the Drive Sled Number. The disk
drive sled closest to the management card is
always the number 1 disk drive sled

The Drive Sled Number identified in step 2 is
the SledNum variable to be entered into the
CLI commands. Take the disk drive sled offline
by entering the following CLI commands at the
control computer Ready prompt

Set AtaDiskState (SledNum, 1, OFFLINE)

Set AtaDiskState (SledNum, 2, OFFLINE)

Set DriveSledPower (SledNum, OFF)

CAUTION

CAUTION

In a Hot Spare configuration, a drive sled should
only be taken offline if there is absolutely no
activity on that drive. If there is any activity, the
rebuild of the Hot Spare sled may be flawed.

4

Wait 30 seconds for the disk drive sled to spin
down and complete any remaining I/O activity.

5

Unscrew the two screws on the disk drive sled
with the appropriate tool.

6

Carefully pull the disk drive sled out of chassis
using its handle.

7

Mark or tag the disk drive sled with the array
serial number, the date removed, and its slot
number.

8

Place the disk drive sled in an appropriate ESD
container or bag.

9

Install the replacement disk drive sled into the
array chassis using proper ESD control steps
and with the proper orientation (The disk drive
sled assembly is keyed and can only be
inserted one way).

10 Tighten the two screws on the disk drive sled

with the appropriate tool.

11 If you do not have

AutoRebuild enabled

, using

the disk drive sled number identified in step 2,
on the control computer Ready

prompt type

1 2

3

4

5

6 7 8 9 10 11 12

Drive Sleds

Management Card