Hot Spares

To set up one RAID Level 5 group with one Hot
Spare sled

1

Connect to Diamond Storage Array services
(refer to

Accessing the Array

on page 17) and use

the CLI or enter ATTO ExpressNAV interface
Advanced CLI Configuration page.

2

Type set QuickRAID5 1 1

3

Type SaveConfiguration Restart

The array is configured into one RAID Level 5
group with one Hot Spare sled.

To set up two RAID Level 5 groups with Hot
Spare sleds

1

Connect to Diamond Storage Array services
and use the CLI or enter ATTO ExpressNAV
interface Advanced CLI Configuration page.

2

Type set QuickRAID5 2 2

3

Type SaveConfiguration Restart

The array is configured into two RAID Level 5
groups with two Hot Spare sleds.

Exhibit 7.2-1 Configuration of sleds in RAID Level 1: five LUNs with two Hot Spare sleds

Exhibit 7.2-2 Configuration of sleds in RAID Level 10: five mirrored pairs of sleds in one Virtual Drive and two Hot
Spare non-mirrored sleds

Exhibit 7.2-3 Configuration of sleds in RAID Level 5

Sled

1

2

3

4

5

6

7

8

9

10

11

12

Drive

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

QuickRAID5 1

LUN 1

Hot

Spare

QuickRAID5 2

LUN 1

LUN 2

Hot

Spare

Hot

Spare

1 Virtual Drive

2 Hot Spare sleds