Configuring a partially-populated array – ATTO Technology Diamond Storage Array S-Class User Manual

Page 72

Advertising
background image

61

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

Configuring a partially-populated array
The simplest way to attain RAID Level 5 in a
partially-populated array (an array with three or
more sleds but less than 12 sleds) is to create one
RAID Level 5 group, with or without hot spare

sleds, encompassing all the available sleds by
using the CLI command

QuickRAID5 ALL

.

To set up a partially populated arrays, you must
have at least three sleds filling contiguous slots as
shown in Exhibit 6.4-4, beginning with the slot
closest to the management card.

Exhibit 6.4-4 Examples of RAID Level 5 configurations in partially-populated array with at least six sleds. Hot Spare
sleds are in the highest slot numbers.

To set up RAID Level 5 groups

1

Connect to Diamond Storage Array services via
the RS-232 port or the optional Ethernet
management services card (refer to

Accessing

the Array

on page 17). You should now be in the

CLI.

2

Continue with the CLI or access the RAID page
of the ExpressNAV interface (refer to

ATTO

ExpressNAV: Browser-based Interface

on page 25).

Note

Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in
ExpressNAV.

3

Decide the RAID Level 5 configuration you
want based on the number of sleds you are
using and Exhibit 6.4-4 above.

4

Type set QuickRAID5 [2 | 3 | 4 | ALL]

5

Type SaveConfiguration Restart to save the
RAID Level 5 configuration.

6

A Ready prompt displays. You must zero all
drives and parity to make all RAID Level 5
drives coherent. Type RAID5ClearData al

l

CAUTION

CAUTION

This is a destructive operation: all
information stored on these drives is lost.

DO NOT interrupt power until the
RAID5ClearData operation has completed
(three to six hours).

Sled

1

2

3

4

5

6

7

8

9

10

11

12

QuickRAID5 4
3 contiguous sleds in slots 1-3
and slots 4-6 with no Hot Spare
sled

LUN1

LUN 2

QuickRAID5 3
4 contiguous sleds in slots 1-4
and slots 5-8 with no Hot Spare
sled

LUN 1

LUN 2

QuickRAID5 2
6 contiguous sleds in slots 1-6
with no Hot Spare sled

LUN 1

QuickRAID5 2 1
5 contiguous sleds in slots 1-5
with up to 2 Hot Spare sleds

LUN 1

Hot

Spare

QuickRAID5 ALL
3-12 contiguous sleds with no
Hot Spare sleds

LUN 1

QuickRAID5 ALL 1
3-11 contiguous sleds with 1 Hot
Spare sled

LUN 1

Hot

Spare

Advertising