7 raid interleave parameters, To change the raid interleave parameter – ATTO Technology Diamond Storage Array S-Class User Manual

Page 78

Advertising
background image

67

ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual

6.7 RAID Interleave Parameters

The interleave size sets the amount of data to be written to each drive in a RAID Level group. This is a
tunable parameter which takes a single stream of data and breaks it up to use multiple disks per I/O
interval.

CAUTION

CAUTION

Changing this parameter causes all
previous drive data on the Diamond
Storage Array to be erased. Make sure you
back up all information before setting up
different interleave sizes.

The default sector interleave set by the

QuickRAID

command is 128 blocks (64k). The CLI
command,

RAIDInterleave

, allows you to change

the size of the sector interleave between RAID
groups. The value depends upon the normal
expected file transfer size. If the normal file
transfer size is large, the interleave value should
be large, and vice versa.

The value entered for the RAIDInterleave
command refers to blocks of data: one block is
equivalent to 512 bytes of data.

To change the RAID Interleave parameter

1

Connect to Diamond Storage Array services via
the RS-232 port or the optional Ethernet
management services card (refer to

Accessing

the Array

on page 17). You should now be in

Command Line Interface.

2

Continue with the CLI or access the RAID page
of the ExpressNAV interface (refer to

ATTO

ExpressNAV: Browser-based Interface

on page 25).

Note

Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in
ExpressNAV.

RAIDInterleave options are 16, 32, 64, 128, 256
blocks and span. Span is not available for RAID
Level 5.

3

In all RAID levels except RAID Level 5, type

set RAIDInterleave [16|32|64|128|256| span]

For RAID Level 5 type

set RAIDInterleave [16|32|64|128|256]

4

Information displays on the screen while the
array updates NVRAM ending with a Ready

*.

5

Type SaveConfiguration.

6

Type

FirmwareRestart to reboot the array.

7

Reboot the host computer connected via Fibre
Channel or SCSI to the array.

8

The array is now configured. To verify the
configuration, type

get

RAIDInterleave.

Advertising