To synchronize mirrored drives manually – ATTO Technology Diamond Storage Array S-Class User Manual

Page 77

Advertising
background image

66

You must use a SaveConfiguration Restar

t

command to implement the rebuild priority
command.

To synchronize mirrored drives manually

1

Connect to Diamond Storage Array services via
the RS-232 port or the optional Ethernet
management services card (refer to

Accessing

the Array

on page 17). You should now be in

CLI.

2

Continue with the CLI or access the RAID page
of the ExpressNAV interface (refer to

ATTO

ExpressNAV: Browser-based Interface

on page 25).

3

If AutoRebuild has not been disabled, type

set AutoRebuild disabled saveconfiguration

restart.

4

After the array reboots and completes its
diagnostics, enter the CLI and type
RAIDManualRebuild L S where L is the LUN
and S

is the sled to be rebuilt.

This procedure may take a few hours,
depending on the size of the LUN.

5

To check the rebuild status, type

RAIDRebuildStatus

Advertising