Disconnect port, Input cascade selection, Lock port – AMX UDM-0404 User Manual

Page 97

Advertising
background image

UDM Hub Control Protocol

85

UDM-0404 4x4 Multi-Format Distribution Hub

Input type can have the following values:

Return Status:

Disconnect Port

Disconnects the current input from the Port specified by the Port property, or if non-zero, from the port
specified in the command.

Return Status:

Input Cascade Selection

Each input in the UDM can either come from the VGA connector on the hub or from the cascade connector of
another upstream hub. This command selects this option for each of the four VGA ports.

Cascade value takes the following values:

Return Status:

Lock Port

Locks the port (or range of ports) specified by the Port property, or if non zero, the port specified in the
command, so that the connected input may no longer be changed on that port.

Return Status:

Value

Description

0

VGA

1

Composite (CVBS)

2

S-Video

3

Component analog (YPbPr)

4

TV (from TVM)

Byte #

0

1

2

3

4

5

Byte value

1

Status

Port

Input Selected

Sub Input

Input Type

Byte #

0

1

2

3

4

5

Byte value

6

User Defined

Port

User Defined

User Defined

User Defined

Byte #

0

1

2

3

4

5

Byte value

6

Status

Port

User Defined

User Defined

User Defined

Byte #

0

1

2

3

4

5

Byte value

9

User Defined

Input

Cascade value

User Defined

User Defined

Value

Description

0

No cascade - VGA input

1

Cascade from upstream hub

Byte #

0

1

2

3

4

5

Byte value

9

Status

Port

User Defined

User Defined

User Defined

Byte #

0

1

2

3

4

5

Byte value

2

User Defined

Port

User Defined

User Defined

User Defined

Byte #

0

1

2

3

4

5

Byte value

2

Status

Port

User Defined

User Defined

User Defined

The status return is a copy of the command with the first user defined byte replaced
by a status value - status values are described in a separate section.