PROBLEM

PROBABLE CAUSE

REMEDY

TROUBLESHOOTING (cont.)

Incorrect coffee grind dispensed.

Excessive chaff

Grinder only dispenses from one

hopper

Timer will not display or displays

incorrectly.

Incorrect weight of coffee dis-

pensed

1. Burr adjustment

1. Dechaffer

1. Hopper selector switch (Model

LPG-2E only)

1. Digital Timer

1. Grinder scale requires calibra-

tion.

2. Funnel handle touched during

grinding.

Refer to the Adjustment section

in the Installation and Operation

Manual.

Replace the dechaffer springs.

Replacement dechaffer springs are

provided in the literature package

accompnting the grinder.

Refer to Service - Hopper selector

switch for testing procedures.

(A) Unplug the grinder. Wait a few

seconds and plug it in again.

(B) Refer to Service - Timer for test-

ing procedures.

Refer to GRINDER SCALE CALI-

BRATION procedure.

Do not touch funnel or funnel han-

dle during grinding operation.

41545 072710