Service (cont.) – Bunn G9-2T DBC User Manual

Page 54

Advertising
background image

54

SERVICE (Cont.)

EMI Filter (Models FPG & FPG-2)

FIG 60 EMI FILTER

FIG 61 EMI FILTER TERMINALS

Location:

The EMI Filter is located inside the rear cover of the

grinder housing.
Test Procedure:

1. Disconnect the dispenser from the power source.

2. Disconnect the two red wires and two white wires on

the EMI Filter from the EMI Filter wiring harness.

3. Check for resistance between the two red leads on

the EMI Filter. (Fig 61)

If resistance is present as described the EMI Filter is

operating properly.

If resistance is not present as described, replace the

EMI Filter.

Removal and Replacement:

1. Disconnect the wires from the EMI Filter.

2. Remove the two screws securing the EMI Filter.

3. Remove and discard EMI Filter.

4. Install new EMI Filter using two screws to secure

EMI Filter to its former location.

5. Refer to schematic when reconnecting the wires.

118.0 kΩ - 118.5 kΩ

Across either pair

GRINDER

D

BC

®

41545 122209

Advertising
This manual is related to the following products: