SERVICE (Cont.)

+

A

C

A

C

Removal and Replacement:

1. Disconnect the wires from the rectifier.

2. Remove the #10-32 screw securing the rectifier

to the motor mounting bracket.

3. Remove the rectifier and discard.

4. Install new rectifier on the rear of the motor mount-

ing bracket and secure with a #10-32 screw.

5. Refer to Fig. 37 and reconnect the wires.

BLK from Motor (+)

BLU to BLU from Motor (AC)

WHI from Main Harness (AC)

RED from Motor (-)

FIG. 37 RECTIFIER TERMINALS

P1381

Rectifier (Models G1 MD, FPG-2 DBC)

FIG. 36 RECTIFIER

P1706

Location:

The rectifier is located inside the grinder housing

mounted on the rear of the motor mounting bracket

for models G1 MD and on the component mounting

bracket for model FPG-2 DBC.

Test Procedures:

1. Disconnect the grinder from the power source.

2. Remove the red wire and the black wire from the

rectifier.

3. Check the voltage across the (+) and (-) termi-

nals on the rectifier with a voltmeter. Connect the

grinder to the power source and start the grinder

motor. The indication must be approximately 108

volts dc.

4. Disconnect the grinder from the power source.

If voltage is present as described, the rectifier is op-

erating properly.

If voltage is not present as described, refer to the

grinder wiring diagram and check the grinder wiring

harness.