Service (cont.) – Bunn G9-2T DBC User Manual

Page 43

Advertising
background image

43

SERVICE (Cont.)

Location:

The slide plates are located on the solenoid mount-

ing plate immediately beneath the hopper openings.

The slide plates must always remain flat for proper

operation.

Test Procedure:

With the solenoid mounting plate attached to the

hopper, push the solenoid plunger into the coil. The

slide plate must move freely in the assembly and snap

closed when the plunger is released. Repeat for the

other slide plate.

If the slide plates move as described, they are

operating correctly.

If the slide plates do not move as described, the

problem may be in any one or more of the linkage pieces,

springs, slide plates, and/or the solenoid mounting plate.

Disassemble the solenoid mounting plate assembly and

inspect all components for free movement.

Replace if excessively worn or damaged.

I.

J.

K.

L.

M.
A.
B.
C.
D.
E.
F.
G.
H.

P608

A. Solenoid Coil

B. Fiber Washer

C. Spring

D. Spring Retaining Washer

E. Solenoid Plunger

F. Snap Ring

G. Short Link

H. Long Link

I. Slide Plate

J. Pivot Pin

K. Stop Block

L. Solenoid Mounting Plate

M. Solenoid Limit Thermostat

Removal and Replacement:

1. Remove the hopper from the grinder.

2. Remove six slotted head screws holding the sole-

noid mounting panel to the hopper.

3. The slide plate with attached linkage can be lifted

off the pivot pin and removed with the solenoid

plunger.

4. Refer to the illustration above when reassembling

the components.

5. Inspect the slide plates after reassembly.

They must move freely.

Hopper Slide Plates (Models G9-2, G9-2 DBC)

FIG 44 HOPPER SLIDE PLATES

41545 122209

Advertising