Location:

The timer is located on the timer bracket in the

grinder base. The bracket can be removed by loosening

the two 8-32 screws beneath the timer dial(s).

Test Procedure:

1. Disconnect the grinder from the power supply.

2. Check the voltage across terminals TL1 & TL2 with

a voltmeter when the “Off/On/Start switch is placed

in the “START” (right) position and released. Con-

nect grinder to the power supply. The indication

must be:

(a) 120 volts ac for two wire 120 volt models.

(b) 240 volts ac for two wire 240 volt models.

3. Disconnect the grinder from the power supply.

If voltage is present as described, proceed to step 4.

If voltage is not present as described, refer to the Wiring

Diagram and check the grinder wiring harness.

4. Remove the white/orange and white/yellow wires

from terminals TL3 & TL5.

5. Check for continuity across the white/orange and

white/yellow wires when the Off/On/Start switch

is placed in the “START” (right) position.

If continuity is present as described, reconnect the

white/orange wire to terminal TL3 and the white/yellow

wire to terminal TL5, and proceed to step 6.

If continuity is not present as described, refer to the Wir-

ing Diagram and check the grinder wiring harness.

6.

Check the voltage across terminals TL1 and TL4

with a voltmeter when the Off/On/Start switch

is placed in the “START” (right) position and

released. Connect grinder to the power supply.

The indication must be:

(a) 120 volts ac for two wire 120 volt models.

(b) 240 volts ac for two wire 240 volt models.

7.

Disconnect the grinder from the power supply.

If voltage is present as described, the timer is operating

properly. Refer to the Adjustments section to vary the

amount dispensed.

If voltage is not present as described, replace the

timer.

Removal and Replacement:

1. Remove all wires from the timer terminals.

2. Remove the four 6-32 screws and nuts holding the

circuit board to the timer bracket.

3. Remove the two 6-32 screws and nuts holding the

dial plate to the timer bracket.

4. Install the new dial plate and circuit board to the

timer bracket.

5. Refer to the illustration below when reconnecting

the wires.

6. Refer to the Adjustments section to vary the amount

dispensed.

MINUTE

S

BUNN-O

-MA

TIC

P/N 262

0-

120

VAC

MIN

UTE

S

BUNN-O-MA

TIC

P/N

2620-

12

0 VAC

MINUTES

BUNN-O-MA

TIC

P/N 2620- 120

VAC

2

3

4

5

WHI/RED to Relay N.O.

WHI/RED to

Off/On/Start Switch

WHI to Cordset (120 v)

RED/BLK to Cordset (240 v)

WHI/ORA to

Off/On/Start Switch

WHI/GRN to Relay Coil

WHI/YEL to

Off/On/Start Switch

P1312

P1313

Single set timer shown

Multi set timer (Urn/Carafe) connections are the same

Single set timer shown

Multi set timer (Urn/Carafe) similar

Timer (Model G9)

FIG 50 TIMER

FIG 51 TIMER TERMINALS

41545 122209