SERVICE (Cont.)

Funnel Sensing Coil (Models MHG & G9-2 DBC)

Location:

The funnel sensing coil is located inside of the coil

cover.

Test Procedure:

1. Disconnect the grinder from the power supply.

2. Remove the two 6-32 screws attaching the coil

cover to the front of the grinder housing.

3. Pull slightly away from the housing and disconnect

the two wires from the coil.

4. With an ohmmeter, measure the resistance across

the pin terminals of the coil. The reading should be

5 to 7 ohms.

If this amount of resistance is not present, replace the

funnel sensing coil.

FIG 62 FUNNEL SENSING COIL

FIG 63 FUNNEL SENSING COIL TERMINALS

Removal and Replacement

1. Disconnect the grinder from the power supply.

2. Remove the two 6-32 screws attaching the coil

cover to the grinder housing.

3. Pull slightly away from the housing and disconnect

the two wires from the coil.

3. Remove the coil from the coil cover.

4. Place the new coil into the coil cover and attach the

two wires previously removed.

5. Secure cover with two 6-32 screws.