Service (cont.) – Bunn G9-2T DBC User Manual

Page 39

Advertising
background image

39

SERVICE (Cont.)

Location:

The relay is located on the timer bracket in the

grinder base. The bracket can be removed by loosening

the two 8-32 screws beneath the timer dial.

Test Procedure:

1. Disconnect the grinder from the power supply.

2. Check the voltage across the white/red and white/

green wires of the relay coil with a voltmeter when

the Off/On/Start switch is placed in the “START”

(right) position and released. Connect grinder to

the power supply. The indication must be:

(a) 120 volts ac for two wire 120 volt models

(b) 240 volts ac for two wire 240 volt models for

the approximate setting on the timer.

3. Disconnect the grinder from the power supply.

If voltage is present as described, reconnect the

white/red and white/green wires to the relay coil, and

proceed to step 4.

If voltage is not present as described, refer to the

Wiring Diagrams and check the grinder wiring har-

ness.

4. Remove the white/red and white/blue wires from

the relay contacts.

5. Check for continuity across the relay contacts

when the Off/On/Start switch is placed in the

“START” (right) position and released. Connect

grinder to the power supply. Continuity must

be present for the approximate setting on the

timer.

6. Disconnect the grinder from the power supply.

If continuity is present as described, reconnect the

white/red and white/blue wires, the relay is operating

properly.

If continuity is not present as described, replace

the relay.

Removal and Replacement

1. Remove all wires from the relay terminals.

2. Remove the 6-32 screw fastening the relay to the

timer bracket.

3. Mount the new relay to the timer bracket and

tighten the screw.

4. Refer to the illustration below when reconnecting

the wires.

WHI/BLU to Motor L1

WHI/GRN to Timer L4

WHI/RED to Timer TL1

P610

MINUTE

S

BUNN-O

-MA

TIC

P/N 262

0-

120

VAC

MIN

UTE

S

BUNN-O-MA

TIC

P/N

2620-

12

0 VAC

P1312

Single set timer shown

Multi set timer (Urn/Carafe) similar

Relay (Early Model G-9)

FIG 38 RELAY

FIG 39 RELAY TERMINALS

41545 122209

Advertising