6 i2c diagnostics, I2c diagnostics, Service mode how to select – Barco CINE7 R9010050 User Manual

Page 101: What can be seen, How to select

Advertising
background image

9. Service Mode

How to select

1. Push the cursor key

or

to highlight Memory Banks. (menu 9-41)

2. Press ENTER to toggle between ON and OFF.

ON

different memory banks available

OFF

only one memory bank available.

If different memory banks are available for a source and the memory bank option is toggled to OFF, only the first memory bank
will be used to display the source.

COMMON SETTINGS

G2 ADJUSTMENT

CRT RUN IN CYCLE

PROJECTOR WARM UP

MEMORY BANKS

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-41

How to create a new memory blank

1. Select your source. The projector selects the last used memory bank.

2. Press ENTER.

3. Push the corresponding digit (between 1 and 8) of a non existing memory bank. (The memory banks can be created in random

order, e.g. first creating bank 5 and later bank 2.)

4. Make the necessary adjustments. When leaving the source, the new created memory bank will be saved for later use.

When source 1, video 15.6 kHz /60Hz is create on bank 4 and the vertical frequency changes to 50Hz, the projector will create
a new block (due to the vertical frequency change) with the same bank number 4.

How to recall a specific memory bank for the actual source?

When the memory bank option is ON and a source is selected, this source will be displayed with the last used memory bank settings.
An on-screen menu will give a indication of the memory bank number used. To switch to another memory bank :

1. Press ENTER to select the next memory bank in increasing order.

Or,
Enter the number of the desired memory bank with the digit keys.

9.6 I2C Diagnostics

What can be seen?

The I2C diagnostics menu gives an overview of the I2C failures inside the projector.

To scroll through the failure list, push the cursor key

or

. The I2C address, IC number and module name will be given in I2C

diagnostic menu. When no errors are detected, the following message will appear on the screen : "No errors on i2c-bus detected".

How to select

1. Push the cursor key

or

to highlight I²C Diagnostics. (menu 9-42)

2. Press ENTER to display the diagnostic menu. (menu 9-43)

SERVICE MODE

PROJECTOR SET UP

MEMORY MANAGEMENT

COMMON SETTINGS

I2C DIAGNOSTICS

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-42

I2C DIAGNOSTICS

Failures :
Add IC number Mod. name
48H

IC200

DECODER

Scroll with

or

then <ENTER>

<EXIT> to return

Menu 9-43

R5976584 BARCO CINE7 26022003

97

Advertising