9. Service Mode

By default the Baudrate is set to 9600.

How to Change the Baudrate?

1. Push the cursor key

or

to highlight Change Baudrate and press ENTER to select. (menu 9-15)

The Baudrate menu will be displayed, the actual Baudrate will be highlighted. (menu 9-16)

2. Push the cursor key

or

to highlight the desired Baudrate and press ENTER to confirm.

3. Press EXIT to return to the Projector Set-Up menu.

PROJECTOR SET-UP

IDENTIFICATION
TOTAL RUN TIME

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJECTOR ADDRESS

CHANGE BAUDRATE

POWER UP MODE: operating

COMMON ADDRESS: 0

BARCO LOGO

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-15

BAUDRATE

Select new
baudrate:
9600

4800

2400

1200

600

300

150

Select with arrow

keys:

<ENTER> to accept

<EXIT> to return

Menu 9-16

9.3.8

Power Up Mode Operating/Stand-By

What can be done?

When pressing the power switch, the projector can start up in ’operating mode’ or in ’stand-by mode’.

Operating

The projector start up and displays image.

Stand-By

The projector start up in stand-by and waits until the stand-by button or a digit key is pressed

How to toggle Power Up Mode Operating/Stand By?

1. Push the cursor key

or

to highlight Power Up Mode .. (menu 9-17)

2. Press ENTER to select to toggle between Operating and Standby.

PROJECTOR SET-UP

IDENTIFICATION
TOTAL RUN TIME

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJECTOR ADDRESS

CHANGE BAUDRATE

POWER UP MODE: operating

COMMON ADDRESS: 0

BARCO LOGO

Select with

or

then <ENTER>

<EXIT> to return

Menu 9-17

9.3.9

Common Address

What can be done?

Every projector listens to a common address. This common address can be set to ’0’ or ’1’. When a RCU is programmed with that
common address, every projector with that same common address will follow up the commands given by that RCU.

Why 2 different Common Addresses?

The reason to have the choice to select between common addresses is, to avoid controlling of other IR controlled units, e.g. a TV
set with standard common address 0.