To change elements:

1. Pull the air cleaner cover lock (1) OUT, turn the air cleaner cover (2)

counter-clockwise and remove cover from air cleaner canister (3).

2. Remove the primary element (4). Inspect element for damage.

Damaged elements should not be reused.

3. Thoroughly clean the interior of the air filter canister (5) and vacua-

tor valve (6).

4. If replacing the inner safety element (7) at this time, carefully slide

the inner safety element out. Always discard this element and
replace with a new element.

5. Slide the new primary element over the inner safety element mak-

ing sure the sealing edge is flush with the base of the air cleaner.

IMPORTANT! DO NOT apply any type of petroleum product to the sealing
surface of the filter in an attempt to get a more positive seal. This will cause
sealing surface damage and allow dirt to by-pass the filter. Use liquid
dishwashing soap (Ivory, Dawn, etc.) on the seal of the filter only.

6. Position canister cover (8) in place, turn clockwise to lock into posi-

tion and secure in place by pushing the air cleaner cover lock (9) all
the way in.

OA1290