4. Position the towing vehicle in place. Attach any chains needed to

secure the disabled vehicle.

5. Attach a remote portable hydraulic pressurizing unit to the parking

brake gauge port (1) on the secondary function manifold (2)
mounted on the inside wall of the frame (3) on the left side next to
the transmission.

6. Turn the key switch to the ON position (with the engine not run-

ning), release the park brake (park brake switch OFF), and have an
operator seated in the seat.

7. Pressurize the park brake with the pressurizing unit. Close the

pump needle valve on the pressurizing unit.

CAUTION:

DO NOT exceed 575 psi (40 bar) when pressur-

izing the park brake. Applying too much pressure may damage
the brake seals.